Instutional
Sustainability
R&D
Working With Pluskim
Pluskim Catalog
Pluskim Presentation
Pluskim Blog
Video Gallery
Construction Category
Shoes Slippers Category
Heating Cooling Category
Automotive Category
Furniture Category
Polyurethane Adhesives
Polyester Polyols
Polyurethane Prepolymers
Raw Materials and Auxiliary Chemicals
Polyurethane Spray Foam
PLUSKIM POLYURETHANE SYSTEMS

Pluskim Fire-Resistant Spray Polyurethane Systems

Pluskim manufactures fire-resistant spray polyurethane systems and fire-resistant insulation raw materials for pipe insulation, sandwich panels, and on-site applications; exporting to more than 40 countries.

40+Countries Exported To
2008Years of Industry Experience
B2BCorporate Supply

Pluskim Fire-Resistant Spray Polyurethane Systems — Promotional Video

Overview

What Is Fire-Resistant Insulation?

Fire-resistant insulation is an insulation material system that withstands high temperatures and flame exposure, provides thermal and acoustic insulation, and meets safety standards in industrial facilities. For these systems to be used safely in building construction, their fire behavior must be tested and documented against internationally recognized standards — ASTM E84 in North America and EN 13501-1 in Europe. Pluskim's polyurethane-based fire-resistant insulation raw materials are manufactured for the B2B supply chain covering pipelines, sandwich panels, cold storage facilities, and industrial plant insulation.

🔥

High Temperature Resistance

Closed-cell polyurethane structure forms a layer resistant to high heat and flame exposure.

🧊

Low Thermal Conductivity

The closed-cell structure delivers a low thermal conductivity coefficient, improving energy efficiency while minimizing heat loss.

🏭

Industrial-Scale Production

Bulk production capacity and technical consultancy support for B2B raw material supply.

Fire Performance Standards

ASTM E84 and EN 13501-1 Standards

The correct standard for testing a polyurethane system depends on which market it will be sold in: ASTM E84 is the reference in the US and North America, while EN 13501-1 is the reference in Europe. In Turkey, the European standard is used as the reference under TS EN 13501-1.

ASTM E84 — North American Standard

In the "Steiner Tunnel" test, the material is mounted on the ceiling of a tunnel and exposed to a controlled flame for 10 minutes. The Flame Spread Index (FSI) and Smoke Developed Index (SDI) are measured, and materials are classified as Class A (FSI 0-25, best performance), Class B, or Class C. It is the reference test method for interior surface finishes, acoustic foams, and spray polyurethane foam (SPF) insulation.

EN 13501-1 — European Standard

Also known as the Euroclass system, it classifies materials into seven main classes from A1 (non-combustible) to F. It is further evaluated with smoke production (s1-s3) and flaming droplets/particles (d0-d2) sub-criteria — for example, "B-s1,d0" describes a Class B product with low smoke and no droplets. PU/PIR foam cores used in sandwich panels and spray polyurethane systems receive CE marking under this standard.

Applications

Fire-Resistant Insulation Applications

Polyurethane fire-resistant insulation systems are used across the following industrial and commercial sectors through a B2B supply model.

Pipe Insulation

Filling and insulation for hot/cold water transfer pipes, central heating systems, and natural gas and oil transfer lines.

Sandwich Panels

Fire-resistant polyurethane and PIR systems for roof and wall sandwich panel manufacturing.

Fire-Resistant Spray Polyurethane Systems

Closed-cell fire-resistant spray polyurethane foam for on-site fire-resistant insulation applications.

Cold Storage & Logistics

Industrial storage insulation that protects against temperature fluctuations.

Technical Details

Technical Specifications

Example product: PLUSOL R-110-xx — a closed-cell polyurethane pipe insulation system.

PropertyValue / Description
StructureClosed-cell, special polyether formulation
Application MethodHigh/low-pressure injection machines
Application AreaSteel, stainless steel, HDPE pipe filling
SectorsConstruction, industrial facilities, heating & cooling, energy
Supply ModelB2B — bulk raw material supply and technical support
FAQ

Frequently Asked Questions

Which sectors use fire-resistant insulation material?

Fire-resistant insulation is widely used in construction, industrial pipelines, sandwich panel manufacturing, cold storage facilities, and heating & cooling systems.

What is the difference between polyurethane fire-resistant insulation and standard insulation?

Fire-resistant insulation systems are formulated to provide additional resistance to high temperatures and flame exposure, aiming to meet industrial safety and regulatory requirements.

What is the difference between ASTM E84 and EN 13501-1?

ASTM E84 is a test method used in North America that measures flame spread and smoke density; EN 13501-1 is the Euroclass system used in Europe (and as TS EN 13501-1 in Turkey), classifying materials from A1 to F.

How can I source fire-resistant insulation raw materials from Pluskim?

Pluskim offers direct raw material supply and technical consultancy to B2B customers; quotes can be requested via the contact form or info@pluskim.com.

Get Technical Support for Your Fire-Resistant Insulation Project

Contact our team for B2B raw material supply, technical documentation, and sample requests.

Request a Quote
Quote Form

Request a Technical Quote

Fill out the form and our technical team will get in touch with you shortly about fire-resistant spray polyurethane systems.